Flowline Products • Chem Resist https://www.chemresist.com/brand/flowline/ Fri, 03 Sep 2021 15:45:39 +0000 en-GB hourly 1 https://www.chemresist.com/wp-content/uploads/2021/08/cropped-favicon-chem-resist-80x80.png Flowline Products • Chem Resist https://www.chemresist.com/brand/flowline/ 32 32 Level Controllers and Indicators for Level Switches https://www.chemresist.com/fluid-transfer/level-controllers-and-indicators-for-level-switches/ Fri, 03 Sep 2021 15:45:39 +0000 https://www.chemresist.com/?post_type=chem_resist_fluid_t&p=2568 The post Level Controllers and Indicators for Level Switches appeared first on Chem Resist.

]]>
  • LC40-42
  • LC90-92
  • LC10
  • LC11
  • LC05-06
Series LC40-42
Classification General purpose
Type Controller
Application Pump, valve or alarm actuation; auto fill or empty with alarms
Mount Rail mount
Strobe Alert
Indication LED
Supply 120 / 240 VAC
Input (1-3) switches
Contact (1-3) SPDT relays
Enclosure NEMA 1
Datasheet Click here
Series LC90-92
Classification Isolation
Type Controller
Application Pump, valve or alarm actuation; auto fill or empty with alarms
Mount Rail mount
Strobe Alert
Indication LED
Supply 120 / 240 VAC
Input (1-2) switches
Contact (1 or 2) SPDT relays
Enclosure NEMA 1
Datasheet Click here
Series LC10
Classification General purpose
Type Controller
Application Pump, valve or alarm actuation
Mount Switch-Pak or sensor mount
Strobe Alert Option
Indication LED
Supply 120 / 240 VAC
Input (1) switch
Contact (1) SPDT relay
Enclosure NEMA 4X
Datasheet Click here
Series LC11
Classification General purpose
Type Controller
Application Auto fill or empty
Mount Smart Trak mount
Strobe Alert Option
Indication LED
Supply 120 / 240 VAC
Input (2) switches
Contact (1) SPDT latching relay
Enclosure NEMA 4X
Datasheet Click here
Series LC05-06
Classification General purpose
Type Junction box
Application Wiring term-ination
Mount Switch-Pak, Smart Trak or sensor mount
Strobe Alert Option
Indication
Supply
Input (1-4) switches
Contact
Enclosure NEMA 4X
Datasheet Click here

Enquire about this product

Send a message to the Chem Resist sales team for more information.

Alternatively, contact us on +44 1924 499466 or enquiry@chemresist.com.

"*" indicates required fields

Name*
Hidden
This field is for validation purposes and should be left unchanged.

The post Level Controllers and Indicators for Level Switches appeared first on Chem Resist.

]]>
Level Controllers and Indicators for Level Transmitters https://www.chemresist.com/fluid-transfer/level-controllers-and-indicators-for-level-transmitters/ Fri, 03 Sep 2021 15:41:33 +0000 https://www.chemresist.com/?post_type=chem_resist_fluid_t&p=2566 The post Level Controllers and Indicators for Level Transmitters appeared first on Chem Resist.

]]>
  • LI55
  • LC52
  • LI25-2
  • LI25-1
  • LI40
Series LI55
Classification General purpose
Type Controller
Application Display + control
Mount Panel mount
Display 6-digit LED
Supply 85-265 VAC (available in VDC)
Contact (0, 2, 4) SPDT relay
Enclosure NEMA 4X faceplate
Datasheet Click here
Series LC52
Classification General purpose
Type Controller
Application Display + control
Mount Rail mount
Display 3.5-digit LED + bar graph
Supply 120 / 240 VAC
Contact (2) SPDT relays
Enclosure NEMA 1
Datasheet Click here
Series LI25-2
Classification Intrinsically safe
Type Indicator
Application Display only
Mount Panel mount
Display 5-digit LCD
Supply 9-30 VDC loop
Contact
Enclosure NEMA 4X faceplate
Datasheet Click here
Series LI25-1
Classification General purpose
Type Indicator
Application Display only
Mount Panel mount
Display 5-digit LCD
Supply 9-30 VDC loop
Contact
Enclosure NEMA 4X faceplate
Datasheet Click here
Series LI40
Classification General purpose
Type Indicator
Application Display only
Mount Panel mount
Display 6-digit LCD
Supply EchoPod sensor
Contact
Enclosure NEMA 4X faceplate
Datasheet Click here

Enquire about this product

Send a message to the Chem Resist sales team for more information.

Alternatively, contact us on +44 1924 499466 or enquiry@chemresist.com.

"*" indicates required fields

Name*
Hidden
This field is for validation purposes and should be left unchanged.

The post Level Controllers and Indicators for Level Transmitters appeared first on Chem Resist.

]]>
Level Switches https://www.chemresist.com/fluid-transfer/level-switches/ Fri, 03 Sep 2021 15:40:37 +0000 https://www.chemresist.com/?post_type=chem_resist_fluid_t&p=2564 The post Level Switches appeared first on Chem Resist.

]]>
  • AX1X
  • AX13
  • AXXX
  • AX23
  • LU10
  • LZ12
  • LV10
  • LO10
Series AX1X
Classification Intrinsically safe or general purpose
Media Liquids
Type Single-point package
Application Bulk storage, IBC or drum, neutralization tank
Function Level switch
Max. length 10′ (3m)
Supply 12-36 VDC
Contact (1-4) SPST relay or SPDT reed
Rating 60 VA or 15 VA
Enclosure NEMA 4X (IP65)
Termination Conduit
Mount 2″ NPT (1 1/2″ G)
Temperature -40º F. (-40º C.) to 176º F. (80º C.)
Max. pressure 150 PSI (10 bar)
Material PP / PVDF
Datasheet Click here
Series AX13
Classification General purpose
Media Liquids
Type Single-point package
Application Bulk storage, IBC or drum, neutralization tank
Function Level shut off
Max. length 10′ (3m)
Supply 120/240 VAC
Contact (1-4) SPST relay or SPDT reed
Rating 250 VAC @ 10A
Enclosure NEMA 4X (IP65)
Termination Conduit
Mount 2″ NPT (1 1/2″ G)
Temperature -40º F. (-40º C.) to 176º F. (80º C.)
Max. pressure 150 PSI (10 bar)
Material PP / PVDF
Datasheet Click here
Series AXXX
Classification Intrinsically safe or general purpose
Media Liquids
Type Multi point package
Application Day tank, skid or machine, cooling tower, waste sump, process tank
Function Level switches
Max. length 10′ (3m)
Supply 12-36 VDC
Contact (1-4) SPST relay or SPDT reed
Rating 60 VA or 15 VA
Enclosure NEMA 4X (IP65)
Termination Conduit
Mount 2″ NPT (G)
Temperature -40º F. (-40º C.) to 176º F. (80º C.)
Max. pressure Atm
Material PP
Datasheet Click here
Series AX23
Classification General purpose
Media Liquids
Type Multi point package
Application Day tank, skid or machine, cooling tower, waste sump, process tank
Function Automatic fill or empty
Max. length 10′ (3m)
Supply 120/240 VAC
Contact (1) SPDT latching relay
Rating 250 VAC @ 10A
Enclosure NEMA 4X (IP65)
Termination Conduit
Mount 2″ NPT (G)
Temperature -40º F. (-40º C.) to 176º F. (80º C.)
Max. pressure Atm
Material PP
Datasheet Click here
Series LU10
Classification Intrinsically safe
Media Liquids
Type Ultrasonic sensor
Application Chemical
Function Level switch
Max. length
Supply 12-36 VDC
Contact (1) SPST relay
Rating 32 VDC (0.5A max)
Enclosure NEMA 6 (IP68)
Termination Cable
Mount 3/4″ NPT (G)
Temperature -40º F. (-40º C.) to 176º F. (80º C.)
Max. pressure 150 PSI (10 bar)
Material PP / PFA
Datasheet Click here
Series LZ12
Classification General purpose
Media Liquids
Type Vibration sensor
Application Wastewater
Function Level switch
Max. length
Supply 12-36 VDC
Contact (1) SPST relay
Rating 60 VA (1A max)
Enclosure NEMA 6 (IP68)
Termination Cable
Mount 3/4″ NPT (G)
Temperature -40º F. (-40º C.) to 176º F. (80º C.)
Max. pressure 150 PSI (10 bar)
Material PP-Ryton
Datasheet Click here
Series LV10
Classification General purpose
Media Liquids
Type Buoyancy sensor
Application Water
Function Level switch
Max. length
Supply
Contact (1) SPST reed
Rating 15 VA (0.25A max)
Enclosure NEMA 6 (IP68)
Termination Cable
Mount 3/4″ NPT (Rp)
Temperature -40º F. (-40º C.) to 176º F. (80º C.)
Max. pressure 25 PSI (10 bar)
Material PP / PVDF
Datasheet Click here
Series LO10
Classification General purpose
Media Liquids
Type Optic sensor
Application Secondary containment
Function Leak detection
Max. length
Supply 12-36 VDC
Contact (1) SPST relay
Rating 60 VA (1A max)
Enclosure NEMA 6 (IP68)
Termination Cable
Mount 3/4″ NPT (G)
Temperature -40º F. (-40º C.) to 176º F. (80º C.)
Max. pressure 150 PSI (10 bar)
Material PP / PFA
Datasheet Click here

Enquire about this product

Send a message to the Chem Resist sales team for more information.

Alternatively, contact us on +44 1924 499466 or enquiry@chemresist.com.

"*" indicates required fields

Name*
Hidden
This field is for validation purposes and should be left unchanged.

The post Level Switches appeared first on Chem Resist.

]]>
Level Transmitters https://www.chemresist.com/fluid-transfer/level-transmitters/ Fri, 03 Sep 2021 15:40:20 +0000 https://www.chemresist.com/?post_type=chem_resist_fluid_t&p=2562 The post Level Transmitters appeared first on Chem Resist.

]]>
  • LU20
  • LU23-29
  • LU80-84
  • DL10
  • DL14
  • DL24
Series LU20
Classification Intrinsically safe
Media Liquids
Application Bulk storage, day tank, waste sump
Condensation Minimal
Range 18′ (5.4m))
Output 4-20 mA
Display Yes
Configuration Push button
Termination Conduit
Mount 2″ NPT (G)
Temperature -4º F. (-20º C.) to 140º F. (60º C.)
Max. pressure 30 PSI (2 bar)
Trans. material PVDF
Datasheet Click here
Series LU23-29
Classification General purpose
Media Liquids
Application Bulk storage, day tank, waste sump
Condensation Minimal
Range 32.8′ (10m)
Output 4-20 mA
Display No
Configuration WebCal software
Termination Cable
Mount 1″, 2″ NPT (G)
Temperature -4º F. (-20º C.) to 140º F. (60º C.)
Max. pressure 30 PSI (2 bar)
Trans. material PVDF
Datasheet Click here

 

Series LU80-84
Classification General purpose
Media Liquids
Application Bulk storage, day tank, waste sump
Condensation Minimal
Range 32.8′ (10m)
Output 4-20 mA
Display Yes
Configuration Push button
Termination Conduit
Mount 1″, 2″ NPT (G)
Temperature -4º F. (-20º C.) to 140º F. (60º C.)
Max. pressure 30 PSI (2 bar)
Trans. material PVDF
Datasheet Click here
Series DL10
Classification General purpose
Media Liquids
Application Chemical feed, skid or machine, IBC or drum
Condensation Minimal
Range 49.2″ (1.25m)
Output 4-20 mA
Display No
Configuration WebCal software
Termination Cable
Mount 1″ NPT (G)
Temperature 20º F. (-7º C.) to 140º F. (60º C.)
Max. pressure 30 PSI (2 bar)
Trans. material PVDF
Datasheet Click here
Series DL14
Classification General purpose
Media Liquids
Application Chemical feed, skid or machine, IBC or drum
Condensation Minimal
Range 49.2″ (1.25m)
Output 4-20 mA + (4) SPST relays
Display No
Configuration WebCal software
Termination Cable
Mount 1″ NPT (G)
Temperature 20º F. (-7º C.) to 140º F. (60º C.)
Max. pressure 30 PSI (2 bar)
Trans. material PVDF
Datasheet Click here
Series DL24
Classification General purpose
Media Liquids
Application Day tank, skid or machine
Condensation Minimal
Range 9.8′ (3m)
Output 4-20 mA + (4) SPST relays
Display No
Configuration WebCal software
Termination Cable
Mount 1″ NPT (G)
Temperature 20º F. (-7º C.) to 140º F. (60º C.)
Max. pressure 30 PSI (2 bar)
Trans. material PVDF
Datasheet Click here

Enquire about this product

Send a message to the Chem Resist sales team for more information.

Alternatively, contact us on +44 1924 499466 or enquiry@chemresist.com.

"*" indicates required fields

Name*
Hidden
This field is for validation purposes and should be left unchanged.

The post Level Transmitters appeared first on Chem Resist.

]]>